A2108
Fully Auto UV Tape Curing System |
|
 |
A2112 Fully Auto UV Tape Curing System |
|
 |
 |
|
|
 |
 |
Automatic metal film frame cassette loader system |
 |
Automatic pick-up arm mechanism, to pick the work piece from the metal film frame
cassette into the UV irradiation chamber |
 |
Automatic detection of work piece present inside the UV irradiation chamber |
 |
Automatic triggering the UV irradiation spiral lamp (ON) to cure the work piece, once
the UV irradiation chamber detected work piece present |
 |
Automatic trigger (OFF) the UV irradiation spiral lamp, once the work piece being
UV cure accordingly to the preset programming cure time set |
 |
Automatic pick-up arm, unload the work piece from the UV irradiation chamber into
the metal frame cassette loader system |
 |
Built in with an UV irradiation curing indicator |
 |
Built in with a preprogramming memory, for 5,6 inches wafer curing timer |
 |
Built in with a preprogramming memory, for 8 inches wafer curing timer |
 |
Built in with a preprogramming memory, for 6 inches metal film frame curing timer |
 |
Built in with a preprogramming memory, for 8 inches metal film frame curing timer |
 |
Built in with a SELF DIAGNOSTIC error code display |
 |
Built in with an ELECTRONIC TOUCH SCREEN |
|
|
(Subjected to change without prior notice) |
 |
 |
High Speed Flash UV Irradiation curing on UV tape. |
 |
 |
No Nitrogen gas required |
 |
 |
No clean gas filter required |
 |
 |
Longer life span on spiral lamp |
 |
 |
Higher throughput |
 |
 |
Capable of UV irradiation for 6 inches wafer |
 |
 |
Capable of UV irradiation for 8 inches wafer |
 |
 |
Capable of UV irradiation for 6 inches metal film frame |
 |
 |
Capable of UV irradiation for 8 inches metal film frame |
|
|
 |
 |
Power Supply |
: 220 - 240 Vac, Single Phase |
 |
 |
Ampere |
:15Amp |
 |
 |
Air Supply |
: 70 to 80 PSI |
 |
 |
Machine Weight |
: 400kg Est |
 |
 |
Dimension |
: 825 (L) x 975 (w) x 1150 (H) mm |
 |
|
|
|
|
 |
|
|
 |
 |
Automatic metal film frame cassette loader system |
 |
Automatic pick-up arm mechanism, to pick the work piece from the metal film frame
cassette into the UV irradiation chamber |
 |
Automatic detection of work piece present inside the UV irradiation chamber |
 |
Automatic triggering the UV irradiation spiral lamp (ON) to cure the work piece, once
the UV irradiation chamber detected work piece present |
 |
Automatic trigger (OFF) the UV irradiation spiral lamp, once the work piece being
UV cure accordingly to the preset programming cure time set |
 |
Automatic pick-up arm, unload the work piece from the UV irradiation chamber into
the metal frame cassette loader system |
 |
Built in with an UV irradiation curing indicator |
 |
Built in with a preprogramming memory, for 8 &12 inches wafer curing timer |
 |
Built in with a preprogramming memory, for 8 & 12 inches metal film frame curing timer |
 |
Built in with a SELF DIAGNOSTIC error code display |
 |
Built in with an ELECTRONIC TOUCH SCREEN |
|
|
(Subjected to change without prior notice) |
 |
 |
High Speed Flash UV Irradiation curing on UV tape. |
 |
 |
No Nitrogen gas required |
 |
 |
No clean gas filter required |
 |
 |
Longer life span on spiral lamp |
 |
 |
Higher throughput |
 |
 |
Capable of UV irradiation for 8 inches wafer |
 |
 |
Capable of UV irradiation for 12 inches wafer |
 |
 |
Capable of UV irradiation for 8 inches metal film frame |
 |
 |
Capable of UV irradiation for 12 inches metal film frame |
|
|
 |
 |
Power Supply |
: 220 - 240 Vac, Single Phase |
 |
 |
Ampere |
:15Amp |
 |
 |
Air Supply |
: 70 to 80 PSI |
 |
 |
Machine Weight |
: 500kg Est |
 |
 |
Dimension |
: 1070 (L) x 1080 (w) x 1150 (H) mm |
|
|
|
 |